Riello SDU 6000 - 6KW

SDU6000

Used

6KW max power, double conversion pure sine wave. Can be used as a stand alone tower or rack unit. These can be output tied, connecting two units to make 12KW max power rating.

New cells installed. 

3D printed input housing.

Optional SNMP card is 204 - normally available (but not included)

Manual available in the downloads tab of this item.

12 month RTB warranty

More details

Warning: Last items in stock!

£ 538.18 tax incl.

ModelsSDU 6000
INPUT
Rated power 6000 VA
Voltage 220 / 230 / 240 V
Voltage tolerance 230 V ±20% full load / 230 V +20% -40% half load
Frequency 50 / 60 Hz ±5
Power factor >0.98
Current distortion ≤2%
BY PASS
Input Voltage tolerance 180 / 264 V (selectable in ECO Mode or SMART ACTIVE Mode)
Frequency tolerance Selected frequency ±5% (selectable by user)
OUTPUT and INVERTER OUTPUT
Rated power 6000 VA
Active power 6000 W
Crest factor (Ipeak/Irms) 3 : 1
Waveform Sinusoidal (Pure)
Frequency 50 / 60 Hz selectable
Voltage distortion with non-linear load <3%
Voltage distortion with linear load <1%
BATTERIES
Type VRLA AGM maintenance-free lead based
Typical recharge time 4-6 h
Communication USB / RS232 / slot for communications interface / REPO + Input contact
Protections Overcurrent - short circuit - overvoltage - undervoltage - temperature - excessive low battery
Noise (at 1 m) <48 [bBA] (ECO Mode)
Operating temperature 0 °C - +40 °C
Relative humidity 5-95% non-condensing
Output sockets Terminal block + 2 IEC 320 C13
Standards European directives: L V 2014/35/EU low voltage; EMC 2014/30/EU electromagnetic compatibility -- Standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; RoHS compliant -- Classification in accordance with IEC 62040-3 VFI - SS - 111
DATA
Weight 46 kg
Dimensions (h w d) 448x131x640 Tower - 3Ux19”x640 Rack mm
Input phases 1
Output phases 1

Simplified installation

  • Can be installed on the floor (tower version) or in rack mount cabinets (rack version). The display panel can be rotated;
  • Low noise (<48 dBA): can be installed in any environment thanks to its high frequency switching inverter and PWM load-dependent digitally controlled fan;
  • Operation guaranteed up to 40 °C (the components are designed for high temperatures and are thus subject to less stress at normal temperatures);
  • Built-in IEC output sockets with thermal protection.

Operating mode selection

Functions can be programmed via software or manually via the front display panel.

  • ON LINE: efficiency up to 95%;
  • ECO Mode: to increase efficiency (up to to 98%), allows for the selection of LINE INTERACTIVE technology (VI) to power low priority loads from the mains supply;
  • SMART ACTIVE: the UPS automatically decides upon the operating mode (VI or VFI) based on the quality of the mains power supply;
  • STANDBY OFF: the UPS can be selected to function only when the mains power supply fails (emergency only mode);
  • Frequency Converter operation (50 or 60 Hz).

High quality output voltage

  • Even with non-linear loads (IT loads with a crest factor of up to 3:1);
  • High short circuit current on bypass;
  • High overload capacity: 150% by inverter (even with mains failure);
  • Filtered, stabilised and reliable voltage (double conversion ON LINE technology (VFI compliant with EN62040-3), with filters for the suppression of atmospheric disturbances;
  • Power factor correction: UPS input power factor close to 1 and sinusoidal current uptake.

Other features

  • Selectable output voltage (220/230/240 V);
  • Auto-restart when mains power is restored (programmable via software);
  • Bypass on: when the machine is switched off, it automatically goes into bypass and battery charge mode;
  • Minimum load switch-off;
  • Low battery warning;
  • Start up delay;
  • Total microprocessor and DSP control;
  • Automatic bypass without interruption;
  • Use of custom power modules;
  • Status, measurements and alarms available on standard backlit display;
  • UPS digital updating (flash memory upgradeable);
  • Output sockets protected with resettable thermal switch;
  • Back-feed protection standard: to prevent energy from being fed back to the network;
  • Manual switching to bypass.
  • Topology On-line / Double conversion

No customer reviews for the moment.

Write a review

Riello SDU 6000 - 6KW

Riello SDU 6000 - 6KW

6KW max power, double conversion pure sine wave. Can be used as a stand alone tower or rack unit. These can be output tied, connecting two units to make 12KW max power rating.

New cells installed. 

3D printed input housing.

Optional SNMP card is 204 - normally available (but not included)

Manual available in the downloads tab of this item.

12 month RTB warranty

30 other products in the same category: