Tags
Cell kits that can be used to rebuild existing battery packs - a cost saving alternative to buying fully assembled battery packs.
You will need to re-use the existing trays/wires/fuses/connectors from your old cellpack.
It requires more time and some basic tools, for example Slotted and Posi-Drive screwdriver, tape, thin pliers, and something st...
Cell kits that can be used to rebuild existing battery packs - a cost saving alternative to buying fully assembled battery packs.
You will need to re-use the existing trays/wires/fuses/connectors from your old cellpack.
It requires more time and some basic tools, for example Slotted and Posi-Drive screwdriver, tape, thin pliers, and something sturdy to disassemble the old cell pack with. The advantage is that your time and effort is rewarded with a cheaper overall price to renew the cells in your UPS.
1U Type UPS Cell Rebuild Kit for IBM 2145UPS-1U 750 (31P1393 CP) and any UPS that has 4x 680AH cells.
Cell kit for the dell 4200W type UPS. This kit is enough to rebuild one UPS. The UPS contains two cell trays, you will need to re-use the wiring and containers.
8x Loose cells to rebuild J727n UPS cellpack. Cells only, you will need to re-use your original cell tray and wiring. Dell PN: 0u041r
Cell kit to rebuild Dell OM901R 36v battery pack for Dell J718N 1000 UPS.This kit comprises of 3 brand new 9AH batteries which carry our 12-month RTB warranty.The Dell J718N UPS, that this cell kit is for, is shown in the photos.We supply just the cells. You will need to re-use your existing tray and wiring harness.
Battery kit to rebuild your existing K789 UPS cell pack. comprises 6x cells 9AH capacity. Its a simple job to replace the cells. Set aside around half an hour to do the task. If you need the fully assembled part, drop us a line. We can supply these sometimes. The price is higher.
Dell 1000VA Tower UPS battery kit. Includes the 3x cells for you to rebuild your existing pack.
Cell kit to rebuild 1x HP R5000 UPS (example UPS PN 628821-002) This is the 18x cells that you need to rebuild the three trays inside the UPS. Order 1x for each UPS you need to rebuild. Cell part number 638829-001.
HP T1500 Tower UPS cell kit. BRAND NEW BATTERIES Comprises the 3x cells needed to rebuild your existing battery pack. It is a simple job to rebuild the pack, taking only minutes, and allowing a large saving over a new pack from HP.
Cell kit to rebuild 1x HP R/T 3000 2u cellpack. Can be used to rebuild 517703-001 (UPS battery)582931-001 (EBM extension battery module - EACH EBM TAKES 2X KITS) We include enough tape to stick the cells back in your existing tray. The kit comprises 10x cells. You need only simple tools and some time to rebuild the packs.
1x HP R/T 3000 2u cellpack. - New cells built into original HP tray, ready for immediate installation.
Cell kit to rebuild 1x R3000XR cellpack. This is compatible both with 204503-001 and 407407-001 We include enough tape to stick the cells back in your existing tray. The kit comprises 10x cells. Rebuilding your pack is a medium difficulty job that can be completed with basic tools within an hour.
Cell kit to rebuild 1x R5500XR cellpack. This kit of 10x brand new cells is to rebuild one cell tray for an R5500XR UPS. Each UPS has two trays, so its normal to order 2x of this kit for each UPS you have. We include enough tape to stick the cells back in your existing tray.
Comprises of the 8x cells needed to rebuild your RBC105. You need to re-use your original metal tray and wiring. Swap over time required is about 15 minutes. Used in SUA3000rmxli3u and SUA2200rmxli3u, and their battery packs SUA48rmxlbp3u
RBC113 battery kit (2x 9AH cells) for BX1400ui Use with your existing wiring. APC made this UPS without giving easy access to the cells (!). It is a medium level pain to get to the cells, but at least the cell cost is nice and cheap. I have taken some photos but also found this video which is excellent. https://www.youtube.com/watch?v=QQdEdNdmlmU
RBC117 Battery pack cell kit. Use this to rebuild your original RBC117 cell tray. You need a posi screwdriver and around 30 minutes to swap the cells over. A pair of pliers and a helper to assist you in closing the case can be of benefit
RBC118 Battery pack cell kit. Use this to rebuild your original RBC118 cell tray. You need a posi screwdriver and around 30 minutes to swap the cells over. A pair of pliers and a helper to assist you in closing the case can be of benefit Note that each external battery module uses 2x RBC118, so its normal to order quantity 2x for each EBM you need to...
RBC123 battery kit (2x 7AH cells) for BR900GI / SMT750RMI2U Use with your existing wiring + mating plate
RBC124 battery kit (2x 9AH cells) for BR1500GI / BR1000GI Use with your existing wiring + mating plate
RBC132 Battery pack rebuild kit. We send you the pre-taped cells for you to rebuild your existing tray. This takes around 20 minutes. Includes 4x brand new cells, pre taped for easy installation.
RBC133 Battery pack rebuild kit. Includes 4x brand new 9AH cells, pre taped for easy installation. We send you the pre-taped cells for you to rebuild your existing tray. This takes around 20 minutes. Prise the old cells up to break the adhesive tape underneath. Loosen all cells so that you have something to lever against before removing any. We use blunt...
Cell kit of 16x cells to rebuild 1x RBC140 pack Each RBC140 comprises a pair of trays, each containing 8x cells
APC RBC141 battery cell kit. This comprises the cells to rebuild 1x RBC141. Note that this pack has triangular profile security screws. You can undo these with a flat blade screwdriver if needs be, but ideally with a triangular security bit. We have made our own triangular profile screwdriver to save time.
Replacement cell pack for the RBC142 type battery. 9AH cells - pre assembled with fuse and ready for installation.
Replacement cell pack for the RBC142 type battery. 9AH cells We send the cells assembled as seen in the photo. You will need to re-use your existing fuse that connects the middle two terminals of the batteries. If you dont have one of these contact us and we can supply one for ~£3 at the time of order.
RBC143 Use this kit to rebuild your existing APC metal tray RBC143. Estimated time to swap the cells is 25 minutes and requires only a posi head screwdriver (#2) and pliers can make it easy to remove the wiring. Includes the raw cells only, you will need to re-use your existing metal tray and wiring harness.
RBC157 Battery pack rebuild kit for SMC1500i-2uC Includes 4x brand new 9AH cells, pre taped.
RBC159 Battery pack rebuild kit for SMC1500i-2uC Includes 4x brand new 9AH cells, pre taped.
This is the cells that you use to rebuild using your original cables to make an RBC18. We tape the cells together in the correct orientation to make this job easier. RBC18 battery pack replacement cells for various 1u high rack mount UPS including : BAY450 PS250 PS250I PS450 PS450I SC450rmi1u
RBC23 Battery pack rebuild kit. 4x brand new 7AH cells, pre taped for easy installation We send you the pre-taped cells for you to rebuild your existing tray. This takes around 20 minutes. Prise the old cells up to break the adhesive tape underneath. Loosen all cells so that you have something to lever against before removing any. We use blunt chisels or...
RBC23 Battery pack rebuild kit. Includes 4x brand new 9AH cells, pre taped for easy installation. We send you the pre-taped cells for you to rebuild your existing tray. This takes around 20 minutes. Prise the old cells up to break the adhesive tape underneath. Loosen all cells so that you have something to lever against before removing any. We use blunt...
RBC24 Battery pack rebuild kit. We send you the pre-taped cells for you to rebuild your existing tray. This takes around 20 minutes. Includes 4x brand new 7AH cells, pre taped for easy installation. Using 7AH cells rather than 9AH makes it cheaper to rebuild the pack, at the cost of reducing the UPS total run-time under load.
RBC24 Battery pack rebuild kit. We send you the pre-taped cells for you to rebuild your existing tray. This takes around 20 minutes. Includes 4x brand new 9AH cells, pre taped for easy installation.
RBC31 Battery pack rebuild kit. We send you the correct cells for you to rebuild your existing tray. This is an easy job and takes around 20 minutes. You will need a pozi drive / cross head screwdriver. Includes 4x brand new 9AH cells.
RBC 32 - cell kit. Comprises 2x cells to rebuild with your existing wiring harness
RBC 33 - cell kit. You need to re-use your existing wiring loom. This is the higher 9AH capacity version yielding longer runtimes.
RBC34 cell kit to rebuild your original RBC34 tray (1x) (comprises 4x cells, with double sided foam tape pre-applied)
RBC43 cell kit to rebuild original RBC43 tray (1x) We made a video showing the wiring layout in case you get stuck: https://youtu.be/bIe0Y-f-Scs
Cell kit of 16x cells to rebuild 1x RBC44 pack Each RBC44 comprises a pair of trays, each containing 8x cells
RBC5 Battery pack - kit form. There is a wire linking the two inner terminals, re use this from your original pack. We class the RBC5 and RBC9 kit as the same thing, the cells are the same - but the link in the middle has the fuse on an RBC9. Because we are supplying just the cells and you re-use your fuse, we can have one listing for both.
RBC 59 - cell kit. Includes the 4x cells needed to rebuild. You will have to re-use your original wiring parts. And need some sellotape to hold the pack together once rebuilt (or you can be careful when you peel off the original tape and re-use that.
RBC 59 - cell kit. Includes the 4x cells needed to rebuild. 9AH (higher capacity) kit - use this if you want a longer runtime than normal (approx 30% increase) You will have to re-use your original wiring parts. And need some sellotape to hold the pack together once rebuilt (or you can be careful when you peel off the original tape and re-use that.
Cell kit for RBC88 type battery pack. The RBC88 is used in the APC SMT1500rmi1u type UPS.
Cell kit to rebuild original SYBT2 tray (each kit rebuilds 1x SYBT2 tray)
32x Cells to rebuild your existing battery module12 Month RTB warranty The time to rebuild one tray is around 30 minutes and requires the original tray, a cross-head screwdriver and possibly some pliers. Rebuilding 4x will take a while so make sure to have a cup of tea and biscuits handy.
CELL KIT TO REBUILD 1X SYBT5 battery. These battery systems are more complex than normal. There is an EEPROM that records when the batteries are old. Once set, even if you install new batteries, the UPS will give an old battery warning. The UPS will still use the new cells, and the runtime will increase, but they will show a warning. We made a video to...
8x Cells to rebuild your existing battery module12 Month RTB warranty The time to rebuild one tray is around 30 minutes and requires the original tray, a cross-head screwdriver and possibly some pliers.
8x Cells to rebuild your existing tray. 12 Month RTB warranty The time to rebuild one tray is around 30 minutes and requires the original tray, a cross-head screwdriver and possibly some pliers.
-----[ UPS-Trader ]---------
15 Grosvenor Grange / Warrington / WA1 4SF
Email: shop@ups-trader.co.uk